{"title":"Oxygen Regulators","description":"\u0026lt;p\u0026gt;TGA-approved medical oxygen and air regulators for cylinder-fed oxygen delivery in clinical and emergency settings. Vectr Medical stocks Gentec and Comweld regulators — including standard piston regulators, multi-flow click-stop models, and pin-index yoke variants — for hospitals, GP clinics, aged care, and emergency response. Fast Australia-wide delivery.\u0026lt;\/p\u0026gt;","products":[{"product_id":"gentec-286-medical-gas-regulator","title":"Gentec 286 Medical Gas Regulator","description":"\u003cp\u003eThe Gentec 286 is a piston-design medical gas regulator built for cylinder-fed oxygen and air supply in clinical and emergency environments. Chrome-plated brass body, sintered bronze inlet filter for long service life, internal relief valve, and a 1.5-inch UL-listed gauge make it a workhorse regulator for ambulance services, hospital wards, and remote-medical kits. Meets CGA standards and ignition testing for oxygen service.\u003c\/p\u003e\n\n\u003ch2\u003eKey Features\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eChrome-plated brass body\u003c\/strong\u003e — durable, corrosion-resistant.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003e3000 psi maximum inlet pressure\u003c\/strong\u003e — handles full medical cylinder pressures.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003e1.5-inch UL-listed gauge\u003c\/strong\u003e — clinical-grade pressure indication.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003ePiston design regulator\u003c\/strong\u003e — robust and reliable.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eSintered bronze inlet filter\u003c\/strong\u003e for long service life.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eEasy-to-read flow rate window\u003c\/strong\u003e.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eMeets ignition testing for oxygen service\u003c\/strong\u003e.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eComplies with CGA standards\u003c\/strong\u003e.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eInternal relief valve\u003c\/strong\u003e.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eHose barb outlet\u003c\/strong\u003e.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003eBody: Chrome-plated brass\u003c\/li\u003e\n  \u003cli\u003eMaximum inlet pressure: 3000 psi\u003c\/li\u003e\n  \u003cli\u003eGauge: 1.5-inch UL-listed\u003c\/li\u003e\n  \u003cli\u003eDesign: Piston regulator\u003c\/li\u003e\n  \u003cli\u003eFilter: Sintered bronze inlet\u003c\/li\u003e\n  \u003cli\u003eOutlet: Hose barb\u003c\/li\u003e\n  \u003cli\u003eStandards: CGA-compliant, ignition-tested for oxygen\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eWhere to use it\u003c\/h2\u003e\n\u003cp\u003eAmbulance services, hospital wards using cylinder-fed oxygen as a backup or primary supply, GP and specialist clinics, military and field medical kits, mining first-aid stations. The piston design and sintered bronze filter make it more durable than diaphragm-style regulators in dusty or harsh environments.\u003c\/p\u003e\n\n\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003e286 vs 197M — which?\u003c\/strong\u003e\u003cbr\u003e286 is piston-design, more rugged for harsh environments. 197M is brass with adjustable yoke and self-sealing outlet — better for clinical settings with frequent flowmeter changeovers. Choose 286 for ambulance and field use, 197M for clinical wards.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat does \"ignition testing for oxygen service\" mean?\u003c\/strong\u003e\u003cbr\u003eOxygen-service equipment must pass tests showing it won't ignite under high-oxygen environments. The Gentec 286 meets these tests, making it safe for oxygen cylinder use. Don't substitute non-oxygen-rated regulators.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat inlet fitting do I need?\u003c\/strong\u003e\u003cbr\u003eSpecify your cylinder type (CGA-870, AS-2473, etc.) when ordering. Different inlets available depending on Australian medical-cylinder standards.\u003c\/p\u003e","brand":"Gentec","offers":[{"title":"Default Title","offer_id":51398760956225,"sku":"GEN-REG-286","price":319.5,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0975\/1550\/3937\/files\/5fe0d70f-1-14.jpg?v=1771288794"},{"product_id":"gentec-197m-medical-gas-regulator","title":"Gentec 197M Medical Gas Regulator","description":"\u003cp\u003eThe Gentec 197M is a high-quality brass medical gas regulator with a matte chrome body, adjustable yoke system, and self-sealing outlet — designed for clinical environments where flowmeters are connected and disconnected frequently. The self-sealing outlet ensures no oxygen flows until the flowmeter is properly connected, reducing waste and preventing accidental discharge into the room.\u003c\/p\u003e\n\n\u003ch2\u003eKey Features\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eHigh-quality brass with matte chrome body\u003c\/strong\u003e — durable, professional finish.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eAdjustable yoke system\u003c\/strong\u003e — fits a range of cylinder valve types.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eEasy-to-read pressure gauge\u003c\/strong\u003e.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eSelf-sealing outlet\u003c\/strong\u003e — no oxygen flows until flowmeter is connected.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003eBody: High-quality brass with matte chrome\u003c\/li\u003e\n  \u003cli\u003eYoke: Adjustable\u003c\/li\u003e\n  \u003cli\u003eOutlet: Self-sealing (oxygen flow gated by flowmeter connection)\u003c\/li\u003e\n  \u003cli\u003eGauge: Pressure indication\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eWhy the self-sealing outlet matters\u003c\/h2\u003e\n\u003cp\u003eIn clinical environments where one regulator may serve multiple flowmeters across rotating shifts and patients, a self-sealing outlet prevents oxygen waste between flowmeter changeovers. It also reduces the risk of accidental high-flow oxygen discharge into the patient room — an oxygen-enrichment fire hazard that conventional regulators don't protect against.\u003c\/p\u003e\n\n\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003e197M vs 286 — which?\u003c\/strong\u003e\u003cbr\u003e197M for clinical wards with frequent flowmeter changeovers (the self-sealing outlet adds value here). 286 for ambulance and field use where the piston design and sintered filter offer more rugged performance.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat does \"adjustable yoke\" mean?\u003c\/strong\u003e\u003cbr\u003eThe yoke is the connection between the regulator and the cylinder valve. An adjustable yoke can fit a wider range of cylinder valve geometries — useful when your supply cylinders may come from multiple sources.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIs this oxygen-service certified?\u003c\/strong\u003e\u003cbr\u003eYes — designed and certified for medical oxygen use. As with any oxygen equipment, never apply oils, lubricants, or solvents to the regulator.\u003c\/p\u003e","brand":"Gentec","offers":[{"title":"Default Title","offer_id":51398760988993,"sku":"GEN-REG-197M-ADJ","price":320.0,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0975\/1550\/3937\/files\/23bd5cf5-1-15.jpg?v=1771288794"},{"product_id":"gentec-197m-oxygen-regulator","title":"Gentec 197M Oxygen Regulator","description":"\u003cp\u003eThe Gentec 197M Oxygen Regulator delivers a fixed 400 kPa output pressure with an 80 L\/min flow rate — purpose-built for Australian medical oxygen cylinder use under the AS 2896 SIS (Sleeve Index System) and AS3840.1 standards. Compact 900g unit with simple-to-read pressure gauge, built-in safety relief valve, and 3-year service intervals make it a low-maintenance regulator for clinical and ambulance applications.\u003c\/p\u003e\n\n\u003ch2\u003eKey Features\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eSimple-to-read oxygen pressure gauge\u003c\/strong\u003e.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eConstant delivery pressure of 400 kPa (fixed)\u003c\/strong\u003e — clinical-standard supply pressure.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eRegulated flow rate: 80 L\/min\u003c\/strong\u003e.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eOutlet connection AS 2896 (SIS) sleeve index for oxygen\u003c\/strong\u003e — Australian medical standard.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eSafety relief valve built in\u003c\/strong\u003e.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003e3-year service intervals\u003c\/strong\u003e.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCompact 900g device weight\u003c\/strong\u003e.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eComplies with AS3840.1\u003c\/strong\u003e.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003e5-year limited warranty\u003c\/strong\u003e.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003eGas service: Medical oxygen\u003c\/li\u003e\n  \u003cli\u003eSet pressure: 400 kPa (fixed)\u003c\/li\u003e\n  \u003cli\u003eFlow rate: 80 L\/min\u003c\/li\u003e\n  \u003cli\u003eOutlet: AS 2896 SIS sleeve index (oxygen)\u003c\/li\u003e\n  \u003cli\u003eService interval: 3 years\u003c\/li\u003e\n  \u003cli\u003eWeight: 900 g\u003c\/li\u003e\n  \u003cli\u003eCompliance: AS3840.1\u003c\/li\u003e\n  \u003cli\u003eWarranty: 5-year limited\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eWhere it fits in the range\u003c\/h2\u003e\n\u003cp\u003eThe 197M Oxygen Regulator is the simpler, fixed-pressure variant in the Gentec 197M family. The 197M Medical Gas Regulator (separate SKU, AU$320) adds an adjustable yoke; the 197M-870-YSC and 197M-950-YSC variants add pin-index yoke designs for specific cylinder valve types. Pick the 197M Oxygen Regulator for standard Australian SIS oxygen output without yoke-system complexity.\u003c\/p\u003e\n\n\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eWhat does AS 2896 SIS mean?\u003c\/strong\u003e\u003cbr\u003eAustralian Standard 2896 specifies the Sleeve Index System for medical gas connections. SIS connections are gas-specific (oxygen, nitrous oxide, medical air) — preventing cross-connection of incompatible gases. Use the right SIS for the gas you're delivering.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIs 80 L\/min enough?\u003c\/strong\u003e\u003cbr\u003eFor most clinical uses, yes. High-flow oxygen therapy (HFOT) and some specialist applications may need higher output — for those, look at the 197M-870-YSC (300 L\/min max).\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat's the service interval really?\u003c\/strong\u003e\u003cbr\u003e3-year scheduled service per Gentec recommendation. Mark service dates on your equipment maintenance log; compliance with AS3840.1 typically requires documented service history.\u003c\/p\u003e","brand":"Gentec","offers":[{"title":"Default Title","offer_id":51398761021761,"sku":"GEN-REG-197M-400","price":281.35,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0975\/1550\/3937\/files\/6ad613e2-1-1.jpg?v=1771288795"},{"product_id":"comweld-series-o-oxygen-regulator","title":"Comweld Series-O Oxygen Regulator","description":"\u003cp\u003eThe Comweld Series-O Oxygen Regulator is a premium clinical regulator featuring Encapsulated Seat Technology (EST) for surge resistance and accuracy, a large-diameter diaphragm normally found only in double-stage regulators, and a triple-filter system that prevents particle contamination of the high-pressure gas path. Tamper-resistant design, colour-coded gas-specific identification, and tool-free routine disconnection make it suited to high-traffic clinical environments where reliability and safety are non-negotiable.\u003c\/p\u003e\n\n\u003ch2\u003eKey Features\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eEncapsulated Seat Technology (EST)\u003c\/strong\u003e — superior performance, accuracy, and resistance to surging.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eLarge-diameter diaphragm\u003c\/strong\u003e — single-stage regulator with double-stage performance characteristics.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eTriple-filter system\u003c\/strong\u003e — prevents foreign particles reaching the high-pressure gas or seat.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eTool-free routine disconnection\u003c\/strong\u003e from cylinder valve.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eBuilt-in safety relief valve\u003c\/strong\u003e.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eTamper-resistant design\u003c\/strong\u003e — only qualified personnel can adjust internals.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eColour-coded pressure gauges and labels\u003c\/strong\u003e for quick gas identification.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eGas-specific inlet\u003c\/strong\u003e — prevents incorrect gas connection.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003eGas service: Medical oxygen\u003c\/li\u003e\n  \u003cli\u003eTechnology: Encapsulated Seat (EST)\u003c\/li\u003e\n  \u003cli\u003eDiaphragm: Large-diameter (single-stage with double-stage performance)\u003c\/li\u003e\n  \u003cli\u003eFiltration: Triple-filter system\u003c\/li\u003e\n  \u003cli\u003eInlet: Gas-specific medical oxygen\u003c\/li\u003e\n  \u003cli\u003eIdentification: Colour-coded gauges and labels\u003c\/li\u003e\n  \u003cli\u003eTGA-approved for medical use in Australia\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eWhy pay more for Series-O\u003c\/h2\u003e\n\u003cp\u003eThe Comweld Series-O is the premium clinical regulator. The triple-filter system substantially extends regulator life in environments with particulate contamination (older cylinder stocks, dusty supply chains). EST seat technology resists surging during cylinder change-out — a common cause of accuracy drift in basic regulators. Colour-coded labelling speeds gas identification during fast-paced clinical handovers. For ambulance services, ICU, and emergency departments, the upgrade pays for itself in reliability and reduced maintenance overhead.\u003c\/p\u003e\n\n\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eEST — what does it actually do?\u003c\/strong\u003e\u003cbr\u003eThe valve seat is encapsulated in a protective compound that resists wear and surging when the regulator is rapidly pressurised (e.g., when a fresh cylinder is opened). Reduces accuracy drift and extends seat life.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTool-free disconnection — really?\u003c\/strong\u003e\u003cbr\u003eThe regulator can be removed from the cylinder valve without spanners or specialised tools. Useful for fast cylinder swaps in ambulance and emergency-room settings.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIs the tamper-resistant design adjustable by authorised technicians?\u003c\/strong\u003e\u003cbr\u003eYes — the design prevents casual tampering but trained Comweld service technicians can adjust as needed during scheduled service.\u003c\/p\u003e","brand":"Comweld","offers":[{"title":"Default Title","offer_id":51398761382209,"sku":"CWD-REG-SERIES-O-OX","price":396.0,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0975\/1550\/3937\/files\/5c9f4294-518804.jpg?v=1771288795"},{"product_id":"comweld-series-o-air-regulator","title":"Comweld Series-O Air Regulator","description":"\u003cp\u003eThe Comweld Series-O Air Regulator is the medical air variant of the Series-O premium clinical regulator. Same Encapsulated Seat Technology, large-diameter diaphragm, triple-filter system, and tamper-resistant safety design as the oxygen variant — with calibration and a gas-specific inlet for medical air supply. Suited to clinical environments running blended-gas therapy, ventilator support, or any setup requiring clinical-grade medical air regulation.\u003c\/p\u003e\n\n\u003ch2\u003eKey Features\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eEncapsulated Seat Technology (EST)\u003c\/strong\u003e — surge resistance and accuracy.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eLarge-diameter diaphragm\u003c\/strong\u003e — double-stage-equivalent performance.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eTriple-filter system\u003c\/strong\u003e.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eTool-free routine disconnection\u003c\/strong\u003e.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eBuilt-in safety relief valve\u003c\/strong\u003e.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eTamper-resistant design\u003c\/strong\u003e.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eColour-coded gauges and labels\u003c\/strong\u003e.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eMedical-air-specific inlet\u003c\/strong\u003e.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003eGas service: Medical air\u003c\/li\u003e\n  \u003cli\u003eTechnology: Encapsulated Seat (EST)\u003c\/li\u003e\n  \u003cli\u003eDiaphragm: Large-diameter (single-stage with double-stage performance)\u003c\/li\u003e\n  \u003cli\u003eFiltration: Triple-filter system\u003c\/li\u003e\n  \u003cli\u003eInlet: Gas-specific medical air\u003c\/li\u003e\n  \u003cli\u003eIdentification: Colour-coded gauges and labels\u003c\/li\u003e\n  \u003cli\u003eTGA-approved for medical use in Australia\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eWhy this costs more than the oxygen variant\u003c\/h2\u003e\n\u003cp\u003eThe Series-O Air is priced higher than the Series-O Oxygen (AU$560 vs AU$396). This reflects lower production volumes for medical air regulators (most clinical setups use predominantly oxygen). The components and engineering are equivalent quality. For sites running both oxygen and air regulators, the price difference is unavoidable — pair the right regulator with the right gas regardless.\u003c\/p\u003e\n\n\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eSeries-O Air vs Series-O Oxygen — what's actually different?\u003c\/strong\u003e\u003cbr\u003eInternally, the engineering is similar. Differences: gas-specific inlet (different connection geometry to prevent cross-connection), calibration (oxygen and air have slightly different gas densities affecting flow indication), and labelling (colour-coded for the correct gas).\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan I cross-use?\u003c\/strong\u003e\u003cbr\u003eNo — never. The gas-specific inlet design prevents cross-use, and using the wrong regulator on the wrong gas can damage the regulator and cause patient harm.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhere is medical air actually used?\u003c\/strong\u003e\u003cbr\u003eBlended-gas respiratory therapy (mixing oxygen and air at controlled ratios), ventilator support requiring controlled gas mix, and some specialty therapies. Most home and basic clinical setups use oxygen only.\u003c\/p\u003e","brand":"Comweld","offers":[{"title":"Default Title","offer_id":51398761414977,"sku":"CWD-REG-SERIES-O-AIR","price":560.0,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0975\/1550\/3937\/files\/75ac7baf-518809.jpg?v=1771288795"},{"product_id":"gentec-286mb-15lya-multi-flow-regulator","title":"Gentec 286MB-15LYA Multi Flow Regulator","description":"\u003cp\u003eThe Gentec 286MB-15LYA is a click-stop multi-flow regulator for medical oxygen cylinder use, with 12 discrete flow settings from 0 through 15 L\/min. The click-stop design eliminates flow-setting drift — once dialled to the prescribed flow, the regulator stays put. Chrome-plated brass body, 3000 psi maximum inlet pressure, and 400 kPa set pressure make it suited to standard Australian medical oxygen cylinder supply.\u003c\/p\u003e\n\n\u003ch2\u003eKey Features\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eChrome-plated brass body\u003c\/strong\u003e — durable, corrosion-resistant.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eMedical oxygen use\u003c\/strong\u003e.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003e3000 psi maximum inlet pressure\u003c\/strong\u003e — handles full medical cylinder pressures.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eSet pressure: 400 kPa\u003c\/strong\u003e.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eFlow rate: up to 15 L\/min\u003c\/strong\u003e.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003e12 click-stop flow selection settings\u003c\/strong\u003e: 0, 0.5, 1, 2, 3, 4, 5, 6, 7, 8, 10, 15 L\/min.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eOutlet: 1 x hose barb (flow-controlled)\u003c\/strong\u003e.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003eGas service: Medical oxygen\u003c\/li\u003e\n  \u003cli\u003eBody: Chrome-plated brass\u003c\/li\u003e\n  \u003cli\u003eMaximum inlet pressure: 3000 psi\u003c\/li\u003e\n  \u003cli\u003eSet pressure: 400 kPa\u003c\/li\u003e\n  \u003cli\u003eFlow range: 0 to 15 L\/min (12 click-stop settings)\u003c\/li\u003e\n  \u003cli\u003eOutlet: 1 x hose barb\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eClick-stop vs adjustable knob\u003c\/h2\u003e\n\u003cp\u003eClick-stop multi-flow regulators have discrete flow positions instead of a continuously variable knob. The advantage: prescribed flows are dialled in cleanly without drift, even when handled under stress in an emergency. The trade-off: only the listed flow rates are available — if your prescription is, for example, 9 L\/min, you'd need to step to 10 L\/min (the next click). For most clinical and emergency uses, click-stop is the preferred design.\u003c\/p\u003e\n\n\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003e15LYA vs 25LYA — which?\u003c\/strong\u003e\u003cbr\u003e15LYA maxes out at 15 L\/min flow (this product). 25LYA goes to 25 L\/min for higher-flow oxygen therapy. If your max prescribed flow is ≤15 L\/min, the 15LYA is enough.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat inlet fitting?\u003c\/strong\u003e\u003cbr\u003eStandard Australian medical oxygen cylinder fittings. Specify your cylinder type when ordering — Gentec supplies the matching inlet.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan the click-stops be felt with gloved hands?\u003c\/strong\u003e\u003cbr\u003eYes — the click is a tactile feedback feature designed for use under stress, including with PPE.\u003c\/p\u003e","brand":"Gentec","offers":[{"title":"Default Title","offer_id":51398762561857,"sku":null,"price":209.0,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0975\/1550\/3937\/files\/eb237da6-286MB-15LYA.jpg?v=1771288798"},{"product_id":"gentec-286mb-25lya-multi-flow-regulator","title":"Gentec 286MB-25LYA Multi Flow Regulator","description":"\u003cp\u003eThe Gentec 286MB-25LYA is a click-stop multi-flow regulator for medical oxygen with 12 discrete flow settings from 0 through 25 L\/min — the higher-flow variant of the 286MB-15LYA. The 25 L\/min ceiling supports high-flow oxygen therapy (HFOT), trauma resuscitation, and other clinical scenarios requiring above-standard flow rates. Chrome-plated brass body, 3000 psi inlet, 400 kPa set pressure.\u003c\/p\u003e\n\n\u003ch2\u003eKey Features\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eChrome-plated brass body\u003c\/strong\u003e.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eMedical oxygen use\u003c\/strong\u003e.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003e3000 psi maximum inlet pressure\u003c\/strong\u003e.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eSet pressure: 400 kPa\u003c\/strong\u003e.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eFlow rate: up to 25 L\/min\u003c\/strong\u003e.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003e12 click-stop flow selection settings\u003c\/strong\u003e: 0, 0.5, 1, 2, 3, 4, 5, 6, 8, 10, 15, 25 L\/min.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eOutlet: 1 x hose barb (flow-controlled)\u003c\/strong\u003e.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003eGas service: Medical oxygen\u003c\/li\u003e\n  \u003cli\u003eBody: Chrome-plated brass\u003c\/li\u003e\n  \u003cli\u003eMaximum inlet pressure: 3000 psi\u003c\/li\u003e\n  \u003cli\u003eSet pressure: 400 kPa\u003c\/li\u003e\n  \u003cli\u003eFlow range: 0 to 25 L\/min (12 click-stop settings)\u003c\/li\u003e\n  \u003cli\u003eOutlet: 1 x hose barb\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eWhen you need 25 L\/min\u003c\/h2\u003e\n\u003cp\u003eHigh-flow oxygen therapy (HFOT) commonly runs at 15-30 L\/min depending on patient and prescription. Trauma resuscitation, severe respiratory distress, and some non-invasive ventilation setups also need flows above the standard 15 L\/min ceiling. If your clinical applications regularly exceed 15 L\/min, the 286MB-25LYA is the right choice. For standard 1-15 L\/min oxygen therapy, the 15LYA is more economical.\u003c\/p\u003e\n\n\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003e15LYA vs 25LYA vs 25LY2A — what's different?\u003c\/strong\u003e\u003cbr\u003e15LYA: 15 L\/min max, 12 settings. 25LYA: 25 L\/min max, 12 settings (this product). 25LY2A: 25 L\/min max with piston-design regulator and additional certifications. Choose by max flow needed and clinical-spec requirements.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAre all 12 click-stop positions calibrated?\u003c\/strong\u003e\u003cbr\u003eYes — each click-stop is factory-calibrated against the rated flow. Don't try to dial between clicks; the design assumes discrete settings only.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat inlet?\u003c\/strong\u003e\u003cbr\u003eSpecify your cylinder type when ordering — Gentec supplies the appropriate Australian medical oxygen inlet fitting.\u003c\/p\u003e","brand":"Gentec","offers":[{"title":"Default Title","offer_id":51398762660161,"sku":null,"price":217.35,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0975\/1550\/3937\/files\/a0b29146-286MB-25LYA.jpg?v=1771288797"},{"product_id":"gentec-197m-870-ysc-oxygen-regulator","title":"Gentec 197M-870-YSC Oxygen Regulator","description":"\u003cp\u003eThe Gentec 197M-870-YSC is a pin-index yoke medical oxygen regulator delivering 400 kPa set pressure with a 130 L\/min Q1 valve flow and 300 L\/min maximum flow. Pin-index yoke prevents incorrect cylinder valve pairing — a critical safety feature when multiple gas types are stocked nearby. Adjustable yoke system, easy-to-read pressure gauge, and self-sealing outlet make it well-suited to clinical settings where flowmeters are connected and disconnected frequently.\u003c\/p\u003e\n\n\u003ch2\u003eKey Features\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eMatte chrome body\u003c\/strong\u003e — professional clinical finish.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eAdjustable yoke system\u003c\/strong\u003e with pin-index ‘T’ screw to prevent removal once installed.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eEasy-to-read pressure gauge\u003c\/strong\u003e.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eSelf-sealing outlet ensuring no leaks\u003c\/strong\u003e.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003ePin index yoke\u003c\/strong\u003e prevents accidental cross-connection of incompatible gas cylinders.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eGas service: Medical oxygen\u003c\/strong\u003e.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eSet pressure: 400 kPa\u003c\/strong\u003e.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eQ1 valve flow: 130 L\/min\u003c\/strong\u003e.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eMaximum flow: 300 L\/min\u003c\/strong\u003e.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003eGas service: Medical oxygen\u003c\/li\u003e\n  \u003cli\u003eBody: Matte chrome\u003c\/li\u003e\n  \u003cli\u003eYoke: Adjustable, pin-index\u003c\/li\u003e\n  \u003cli\u003eSet pressure: 400 kPa\u003c\/li\u003e\n  \u003cli\u003eQ1 valve: 130 L\/min\u003c\/li\u003e\n  \u003cli\u003eMaximum flow: 300 L\/min\u003c\/li\u003e\n  \u003cli\u003eOutlet: Self-sealing\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eWhy pin-index yokes matter\u003c\/h2\u003e\n\u003cp\u003ePin-index yokes have specific pin patterns that match only the cylinder valves of the correct gas type. Oxygen cylinders, nitrous oxide cylinders, and medical air cylinders all have different pin patterns — preventing the regulator from mating with the wrong gas cylinder. This is a critical safety feature in environments where multiple gas types are stocked together.\u003c\/p\u003e\n\n\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003e197M-870-YSC vs 197M-950-YSC?\u003c\/strong\u003e\u003cbr\u003e197M-870-YSC is for medical oxygen. 197M-950-YSC has the same form factor and specs but is calibrated and pin-indexed for medical air. Don't substitute one for the other.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat does Q1 valve mean?\u003c\/strong\u003e\u003cbr\u003eQ1 is the rated flow at standard service conditions — 130 L\/min in this case. Maximum flow (300 L\/min) is the absolute peak the regulator can deliver under specific high-pressure conditions.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat's the 'T' screw for?\u003c\/strong\u003e\u003cbr\u003eTightens the yoke onto the cylinder valve and prevents accidental disconnection during transport or use. Required for the regulator to operate safely.\u003c\/p\u003e","brand":"Gentec","offers":[{"title":"Default Title","offer_id":51398762627393,"sku":null,"price":299.0,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0975\/1550\/3937\/files\/25236ff0-197M-870-YSC-1.jpg?v=1771288797"},{"product_id":"gentec-286mb-25ly2a-multi-flow-regulator","title":"Gentec 286MB-25LY2A Multi Flow Regulator","description":"\u003cp\u003eThe Gentec 286MB-25LY2A is the premium-spec multi-flow regulator in the 286MB family — adding a piston regulator design, a 1.5-inch UL-listed gauge, a sintered bronze inlet filter, and CGA-standard compliance to the 25 L\/min flow capacity. Built for clinical and emergency-vehicle use where regulator durability and certification matter, plus oxygen-service ignition testing for safety.\u003c\/p\u003e\n\n\u003ch2\u003eKey Features\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eOxygen use\u003c\/strong\u003e.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eChrome-plated brass body\u003c\/strong\u003e.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003e3000 psi maximum inlet pressure\u003c\/strong\u003e.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003e1.5-inch diameter UL-listed gauge\u003c\/strong\u003e — clinical-grade pressure indication.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eComplies to CGA standards\u003c\/strong\u003e.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eInternal relief valve\u003c\/strong\u003e.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eHose barb outlet\u003c\/strong\u003e.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003ePiston design regulator\u003c\/strong\u003e — robust and reliable.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eSintered bronze inlet filter\u003c\/strong\u003e for longer service life.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eEasy-to-read flow rate window\u003c\/strong\u003e.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eMeets ignition testing for oxygen service\u003c\/strong\u003e.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003eGas service: Medical oxygen\u003c\/li\u003e\n  \u003cli\u003eBody: Chrome-plated brass\u003c\/li\u003e\n  \u003cli\u003eMaximum inlet pressure: 3000 psi\u003c\/li\u003e\n  \u003cli\u003eGauge: 1.5-inch UL-listed\u003c\/li\u003e\n  \u003cli\u003eDesign: Piston regulator\u003c\/li\u003e\n  \u003cli\u003eFilter: Sintered bronze inlet\u003c\/li\u003e\n  \u003cli\u003eOutlet: Hose barb\u003c\/li\u003e\n  \u003cli\u003eStandards: CGA-compliant, ignition-tested for oxygen\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eWhy piston design and ignition testing\u003c\/h2\u003e\n\u003cp\u003ePiston regulators are more durable than diaphragm-style under harsh field conditions — they handle repeated cycling and dust without performance degradation. Ignition testing is a safety certification specific to oxygen-service equipment: oxygen-rich environments can ignite materials that wouldn't burn in normal air, so oxygen-service equipment is tested to confirm it won't ignite under realistic high-flow oxygen conditions. Don't substitute non-oxygen-rated regulators in oxygen service.\u003c\/p\u003e\n\n\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eIs the LY2A worth the upgrade over the LYA?\u003c\/strong\u003e\u003cbr\u003eIf your environment is harsh (ambulance, mining, military) or audit requires UL\/CGA-listed components, yes. For standard clinical or workplace use, the LYA is sufficient at lower cost.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat does the sintered bronze filter actually do?\u003c\/strong\u003e\u003cbr\u003eFilters out particulates from the high-pressure gas flow before they reach the regulator seat. Extends service life significantly in dusty or contaminated supply environments.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eService interval?\u003c\/strong\u003e\u003cbr\u003eFollow Gentec's recommended schedule — typically 3-5 years for piston regulators under standard use. Mark service dates on your equipment maintenance log.\u003c\/p\u003e","brand":"Gentec","offers":[{"title":"Default Title","offer_id":51398762692929,"sku":null,"price":285.0,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0975\/1550\/3937\/files\/d901b84c-286MB-25LY2A.jpg?v=1771288798"},{"product_id":"gentec-197m-950-ysc-oxygen-regulator","title":"Gentec 197M-950-YSC Medical Air Regulator","description":"\u003cp\u003eThe Gentec 197M-950-YSC is the medical-air variant of the 197M-870-YSC oxygen regulator. Same form factor, same flow capacity (130 L\/min Q1, 300 L\/min max), same self-sealing outlet — calibrated and pin-indexed specifically for medical air cylinder use. Adjustable yoke system with pin-index ‘T’ screw prevents incorrect gas cylinder pairing.\u003c\/p\u003e\n\n\u003ch2\u003eNote: this product's title says \"Oxygen Regulator\" but the unit's specifications are for medical air\u003c\/h2\u003e\n\n\u003cp\u003e\u003cstrong\u003eImportant:\u003c\/strong\u003e The current product title in your store says \"197M-950-YSC Oxygen Regulator\" but the manufacturer specifications confirm the YSC-950 variant is for medical air gas service. The pin-index pattern is air-specific, not oxygen. Update the product title to reflect medical air to prevent customer confusion and ordering errors.\u003c\/p\u003e\n\n### Suggested Revised Title:","brand":"Gentec","offers":[{"title":"Default Title","offer_id":51398762725697,"sku":null,"price":369.0,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0975\/1550\/3937\/files\/0909f7eb-197M-950-YSC.jpg?v=1771288798"}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0975\/1550\/3937\/collections\/6ad613e2-1-1.jpg?v=1774394332","url":"https:\/\/vectrmedical.com.au\/collections\/oxygen-regulators.oembed","provider":"Vectr Medical","version":"1.0","type":"link"}